Neutron Health

    Neutron Health / technical document

    Tech Overview

    The internal beta: local patient records, cited clinical decision support, documents, dictation and Clinic Day on one Mac—with clinic-sharing verification and approval still open.

    Section 01 of 6
    01

    Patient records and encounter history

    The internal beta replaces session-only custody with retained local patient records and encounter history. Earlier notes remain read-only history; adding information to a new intake is a deliberate clinician action.

    • Records use append-only events with their sources.
    • Imported patient matches and conflicting information require clinician confirmation.
    • Signed encounter history is preserved when analysis is repeated.
    • Records keep vitals, documented allergies and current medicines; an admin can create a backup of the clinic’s records. The app runs in English, with Spanish and Brazilian Portuguese.
    02

    A separate clinical path

    MedGemma runs locally inside Neutron Health’s clinical workflow, supervised by deterministic safeguards. MedGemma never leaves Neutron Health’s clinical path, and other models do not participate in clinical decisions.

    • Clinical work does not send patient information to a remote AI service.
    • Rule-based safety alerts point out what to recheck, shown beside the model’s analysis.
    • Only update checks, feedback you choose to send and dictation languages an admin installs go online. Offline clinical work does not imply that the entire app can never connect: optional update checks use the internet and contain no patient information. Send Feedback also goes online, but only when the user sends it: text only, no patient data, with a task-board reference. Installing a dictation language needs the internet once; after that, dictation runs on the Mac and keeps no recording.
    03

    Clinician review, signing, and handoff

    The clinical workflow moves from intake through triage, differential assessment, risk, and recommended actions to a clinician’s note, signing, and deliberate handoff. AI output remains distinct from the clinician’s conclusion.

    • Separate rules check missing information, vital signs, and other safety conditions; they are not clinical judgment.
    • Clinicians must verify outputs against examination, local protocols, and their own judgment.
    • Patient information stays on the clinic’s Macs unless deliberately exported. A clinician can export a handoff, and an administrator can create a clinic backup.
    • Matching sources show the intake field or open the PDF passage behind a finding, and the case is shown as a thread. Attached PDFs and photos are read locally, including scanned pages; findings can cite the PDF passage they came from; dictation is included in the beta.
    • Signing and key protections require validation on real Macs; a candidate signature is not evidence of clinical authorization.
    04

    Approved Macs on the clinic network

    The design uses a local clinic hub for encrypted shared records and backups. A clinical administrator approves each joining Mac. Access and administrative actions are recorded.

    • Each Mac runs its own clinical model and retains local work.
    • The hub is designed to store ciphertext rather than readable patient records.
    • Pairing and the standby hub exist; two-Mac checks are still owed. Access controls, key revocation, and standby recovery still need real-Mac checks.
    05

    Outages, backup, and recovery

    The candidate saves work locally when the hub is unavailable. On reconnection, a clinician confirms record merges. The design includes snapshots, a standby copy, and recorded restore checks.

    • Potential duplicates and conflicting clinical information require review.
    • Backup retention and restore behavior must be verified against clinic requirements.
    • Multi-Mac outages, standby switching, and recovery have not yet established field readiness.
    06

    Boundary

    Checking our work

    The internal beta is for evaluation—not a certified or clinically deployed system. Clinical rollout follows certification.

    • Open gates include real-Mac clinic checks, hardware performance, native workflow review, clinical review and Spanish and Portuguese translation review, and applicable regulatory approvals.
    • Clinical prompt or output changes require benchmark checks and clinical review before use.
    • The intended direct-distribution path requires verified archives, notarization, update integrity, administrator-approved installation, and no installation during an encounter.
    • Today: Clinic Day includes the Today calendar, appointments and walk-ins, Flow Board, Pharmacy, Pending Results and Follow-ups on one Mac. Follow-ups and pending results have named owners and due dates; unfinished work returns to an administrator if its owner leaves.
    • Planned: sharing the clinic day across Macs, front-desk and pharmacy roles, a vitals station recording who, where and when, and updates from a drive.
    • Check-in stations are deferred until after certification. Requires a Mac with Apple silicon and macOS 26 or later; 16 GB memory is recommended for evaluation.

    End of document

    Clinician control. Verified before deployment.

    Clinician decision support only. The internal beta is not authorized for clinical deployment. Clinical review, required regulatory approvals, and field validation remain prerequisites.